Directional Control Valve with Inductive Position Control - Series D1VW
Ces vannes fournissent des limitations fonctionnelles élevées jusqu'à 80 l/min en combinaison avec une faible perte de charge conduisant à des économies d'énergies. Elles sont utilisées dans des applications de sécurité pertinentes.
53 références disponibles
| Référence | Code de la bobine | Type de contrôle du positionnement | Option d'électrovanne | Position de la bobine | Tension d'entrée | Matériau du joint |
|---|---|---|---|---|---|---|
D1VW001ENJWI5N | 001 | Start position monitored side B | With manual override | 2 positions, spring offset in position 0, operated in position a | 24 V DC | NBR |
D1VW001ENJWTI5N | 001 | Start position monitored side B | Without manual override | 2 positions, spring offset in position 0, operated in position a | 24 V DC | NBR |
D1VW001FNJWI2N | 001 | End position monitored side B | With manual override | 2 positions, operated in position 0, spring offset in position b | 24 V DC | NBR |
D1VW001KNJWI1N | 001 | End position monitored side A | With manual override | 2 positions, spring offset in position 0, operated in position b | 24 V DC | NBR |
D1VW001KNJWI4N | 001 | Start position monitored side A | With manual override | 2 positions, spring offset in position 0, operated in position b | 24 V DC | NBR |
D1VW001KNJWTI4N | 001 | Start position monitored side A | Without manual override | 2 positions, spring offset in position 0, operated in position b | 24 V DC | NBR |
D1VW001MNJWI1N | 001 | End position monitored side A | With manual override | 2 positions, operated in position 0, spring offset in postion a | 24 V DC | NBR |
D1VW001MNJWI4N | 001 | Start position monitored side A | With manual override | 2 positions, operated in position 0, spring offset in postion a | 24 V DC | NBR |
D1VW002CNJWTI6N | 002 | Start positions | Without manual override | 3 positions, spring offset in position 0, operated in position a or b | 24 V DC | NBR |
D1VW002ENJWTI5N | 002 | Start position monitored side B | Without manual override | 2 positions, spring offset in position 0, operated in position a | 24 V DC | NBR |
D1VW002KNGWI1N | 002 | End position monitored side A | With manual override | 2 positions, spring offset in position 0, operated in position b | 205 V DC | NBR |
D1VW002KNJWI4N | 002 | Start position monitored side A | With manual override | 2 positions, spring offset in position 0, operated in position b | 24 V DC | NBR |
D1VW002KNJWTI4N | 002 | Start position monitored side A | Without manual override | 2 positions, spring offset in position 0, operated in position b | 24 V DC | NBR |
D1VW003FNJWTI2N | 003 | End position monitored side B | Without manual override | 2 positions, operated in position 0, spring offset in position b | 24 V DC | NBR |
D1VW003FNJWTI5N | 003 | Start position monitored side B | Without manual override | 2 positions, operated in position 0, spring offset in position b | 24 V DC | NBR |
D1VW004CNJWI6N | 004 | Start positions | With manual override | 3 positions, spring offset in position 0, operated in position a or b | 24 V DC | NBR |
D1VW004CNJWTI6N | 004 | Start positions | Without manual override | 3 positions, spring offset in position 0, operated in position a or b | 24 V DC | NBR |
D1VW004CVJWTI6N | 004 | Start positions | With manual override | 3 positions, spring offset in position 0, operated in position a or b | 24 V DC | FPM |
D1VW015MNJWTI4N | 015 | Start position monitored side A | Without manual override | 2 positions, operated in position 0, spring offset in postion a | 24 V DC | NBR |
D1VW020BNGWI2N | 020 | End position monitored side B | With manual override | 2 positions, spring offset in position b, operated in position a | 205 V DC | NBR |
D1VW020BNGWI5N | 020 | Start position monitored side B | With manual override | 2 positions, spring offset in position b, operated in position a | 205 V DC | NBR |
D1VW020BNJWI2N | 020 | End position monitored side B | With manual override | 2 positions, spring offset in position b, operated in position a | 24 V DC | NBR |
D1VW020BNUWI5N | 020 | Start position monitored side B | With manual override | 2 positions, spring offset in position b, operated in position a | 98 V DC | NBR |
D1VW020BVJWI2N | 020 | End position monitored side B | With manual override | 2 positions, spring offset in position b, operated in position a | 24 V DC | FPM |
D1VW020BVJWI5N | 020 | Start position monitored side B | With manual override | 2 positions, spring offset in position b, operated in position a | 24 V DC | FPM |
Description
La série D1VW de vanne de commande directionnelle à action directe de Parker a un contrôle de position inductif dans les caractéristiques de faibles pertes d'énergie NG06 (CETOP 03 / NFPA D03) en raison de l'optimisation des passages de débit. Elle offre de hautes limites fonctionnelles jusqu'à 80 l/min et une pression maximale de 350 bar.
Ce distributeur tout ou rien est généralement utilisé dans des applications de sécurité. Elle est conforme à la directive des engins 2006/42/EG pour servir de valve de serrage selon la norme EN 201:2010. La position initiale ou finale peut être surveillée. Le contrôle de position est disponible pour les valves à simple et double bobines.
Marchés :
• Industrie
• Moulage
Caractéristiques/avantages :
• Limites fonctionnelles élevées – les faibles forces garantissent la sécurité d'utilisation même à des débits élevés
• Faible perte de charge pour des pertes d'énergie limitées en cours d'utilisation
• Large gamme de produit offrant – différentes options – toutes les valves d'une seule source
• Délai de livraison court - aucun stockage nécessaire
Applications :
• Tous les types d'applications de sécurité pertinentes
• Moulage par injection (composant de sécurité selon la directive des engins 2006/42/EG)
Attention :
Le réglage du contrôle de la position est définie et scellée en usine. Le remplacement et la réparation ne peuvent être traités que par Parker.
La position en cas de coupure de courant est le ressort de compensation ou la position centrale.