Directional Control Valve with Inductive Position Control - Series D1VW

Directional Control Valve with Inductive Position Control - Series D1VW

Ces vannes fournissent des limitations fonctionnelles élevées jusqu'à 80 l/min en combinaison avec une faible perte de charge conduisant à des économies d'énergies. Elles sont utilisées dans des applications de sécurité pertinentes.

53 références disponibles
RéférenceCode de la bobineType de contrôle du positionnementOption d'électrovannePosition de la bobineTension d'entréeMatériau du joint
D1VW001ENJWI5N

001

Start position monitored side B

With manual override

2 positions, spring offset in position 0, operated in position a

24 V DC

NBR

D1VW001ENJWTI5N

001

Start position monitored side B

Without manual override

2 positions, spring offset in position 0, operated in position a

24 V DC

NBR

D1VW001FNJWI2N

001

End position monitored side B

With manual override

2 positions, operated in position 0, spring offset in position b

24 V DC

NBR

D1VW001KNJWI1N

001

End position monitored side A

With manual override

2 positions, spring offset in position 0, operated in position b

24 V DC

NBR

D1VW001KNJWI4N

001

Start position monitored side A

With manual override

2 positions, spring offset in position 0, operated in position b

24 V DC

NBR

D1VW001KNJWTI4N

001

Start position monitored side A

Without manual override

2 positions, spring offset in position 0, operated in position b

24 V DC

NBR

D1VW001MNJWI1N

001

End position monitored side A

With manual override

2 positions, operated in position 0, spring offset in postion a

24 V DC

NBR

D1VW001MNJWI4N

001

Start position monitored side A

With manual override

2 positions, operated in position 0, spring offset in postion a

24 V DC

NBR

D1VW002CNJWTI6N

002

Start positions

Without manual override

3 positions, spring offset in position 0, operated in position a or b

24 V DC

NBR

D1VW002ENJWTI5N

002

Start position monitored side B

Without manual override

2 positions, spring offset in position 0, operated in position a

24 V DC

NBR

D1VW002KNGWI1N

002

End position monitored side A

With manual override

2 positions, spring offset in position 0, operated in position b

205 V DC

NBR

D1VW002KNJWI4N

002

Start position monitored side A

With manual override

2 positions, spring offset in position 0, operated in position b

24 V DC

NBR

D1VW002KNJWTI4N

002

Start position monitored side A

Without manual override

2 positions, spring offset in position 0, operated in position b

24 V DC

NBR

D1VW003FNJWTI2N

003

End position monitored side B

Without manual override

2 positions, operated in position 0, spring offset in position b

24 V DC

NBR

D1VW003FNJWTI5N

003

Start position monitored side B

Without manual override

2 positions, operated in position 0, spring offset in position b

24 V DC

NBR

D1VW004CNJWI6N

004

Start positions

With manual override

3 positions, spring offset in position 0, operated in position a or b

24 V DC

NBR

D1VW004CNJWTI6N

004

Start positions

Without manual override

3 positions, spring offset in position 0, operated in position a or b

24 V DC

NBR

D1VW004CVJWTI6N

004

Start positions

With manual override

3 positions, spring offset in position 0, operated in position a or b

24 V DC

FPM

D1VW015MNJWTI4N

015

Start position monitored side A

Without manual override

2 positions, operated in position 0, spring offset in postion a

24 V DC

NBR

D1VW020BNGWI2N

020

End position monitored side B

With manual override

2 positions, spring offset in position b, operated in position a

205 V DC

NBR

D1VW020BNGWI5N

020

Start position monitored side B

With manual override

2 positions, spring offset in position b, operated in position a

205 V DC

NBR

D1VW020BNJWI2N

020

End position monitored side B

With manual override

2 positions, spring offset in position b, operated in position a

24 V DC

NBR

D1VW020BNUWI5N

020

Start position monitored side B

With manual override

2 positions, spring offset in position b, operated in position a

98 V DC

NBR

D1VW020BVJWI2N

020

End position monitored side B

With manual override

2 positions, spring offset in position b, operated in position a

24 V DC

FPM

D1VW020BVJWI5N

020

Start position monitored side B

With manual override

2 positions, spring offset in position b, operated in position a

24 V DC

FPM

Description

La série D1VW de vanne de commande directionnelle à action directe de Parker a un contrôle de position inductif dans les caractéristiques de faibles pertes d'énergie NG06 (CETOP 03 / NFPA D03) en raison de l'optimisation des passages de débit. Elle offre de hautes limites fonctionnelles jusqu'à 80 l/min et une pression maximale de 350 bar.

Ce distributeur tout ou rien est généralement utilisé dans des applications de sécurité. Elle est conforme à la directive des engins 2006/42/EG pour servir de valve de serrage selon la norme EN 201:2010. La position initiale ou finale peut être surveillée. Le contrôle de position est disponible pour les valves à simple et double bobines.

Marchés :
• Industrie
• Moulage

Caractéristiques/avantages :
• Limites fonctionnelles élevées – les faibles forces garantissent la sécurité d'utilisation même à des débits élevés
• Faible perte de charge pour des pertes d'énergie limitées en cours d'utilisation
• Large gamme de produit offrant – différentes options – toutes les valves d'une seule source
• Délai de livraison court - aucun stockage nécessaire

Applications :
• Tous les types d'applications de sécurité pertinentes
• Moulage par injection (composant de sécurité selon la directive des engins 2006/42/EG)

Attention :
Le réglage du contrôle de la position est définie et scellée en usine. Le remplacement et la réparation ne peuvent être traités que par Parker.

La position en cas de coupure de courant est le ressort de compensation ou la position centrale.