| Référence | Configuration | Type de commande | Sens de l'écoulement | Pression nominale d'admission maximale | Débit | Matériau du joint | |
|---|---|---|---|---|---|---|---|
DS163 | Normally Closed, Normally Open, Selector | Electrical, Manual | 2-1 De-energized, 3-1 Energized | 3000 PSI, 210 BAR | 11, 12, 13 GAL/MIN, 41.6, 45.4, 49.2 L/MIN | Nitrile | |
DS163B | Normally Closed, Normally Open, Selector | Electrical, Manual | 2-1 De-energized, 2-3 Energized | 3000 PSI, 210 BAR | 7, 14, 15 GAL/MIN, 26.5, 53, 56.8 L/MIN | Nitrile | |
DS163BV | Normally Closed, Normally Open, Selector | Electrical, Manual | 2-1 De-energized, 2-3 Energized | 3000 PSI, 210 BAR | 7, 14, 15 GAL/MIN, 26.5, 53, 56.8 L/MIN | Fluorocarbon | |
DS163V | Normally Closed, Normally Open, Selector | Electrical, Manual | 2-1 De-energized, 3-1 Energized | 3000 PSI, 210 BAR | 11, 12, 13 GAL/MIN, 41.6, 45.4, 49.2 L/MIN | Fluorocarbon | |
DSH083AN | Normally Closed, Normally Open, Selector | Electrical | 2-1 De-energized, 3-1 Energized | 5000 PSI, 350 BAR | 2, 3 GAL/MIN, 7.5, 11.3 L/MIN | Nitrile | |
DSH083AT | Normally Closed, Normally Open, Selector | Electrical, Manual | 2-1 De-energized, 3-1 Energized | 5000 PSI, 350 BAR | 2, 3 GAL/MIN, 7.5, 11.3 L/MIN | D-Ring (Standard) | |
DSH083ATN | Normally Closed, Normally Open, Selector | Electrical, Manual | 2-1 De-energized, 3-1 Energized | 5000 PSI, 350 BAR | 2, 3 GAL/MIN, 7.5, 11.3 L/MIN | Nitrile | |
DSH083ATV | Normally Closed, Normally Open, Selector | Electrical, Manual | 2-1 De-energized, 3-1 Energized | 5000 PSI, 350 BAR | 2, 3 GAL/MIN, 7.5, 11.3 L/MIN | Fluorocarbon | |
DSH083AV | Normally Closed, Normally Open, Selector | Electrical | 2-1 De-energized, 3-1 Energized | 5000 PSI, 350 BAR | 2, 3 GAL/MIN, 7.5, 11.3 L/MIN | Fluorocarbon | |
DSH083B | Normally Closed, Selector | Electrical | 2-1 De-energized, 2-3 Energized | 5000 PSI, 350 BAR | 4 GAL/MIN, 15 L/MIN | D-Ring (Standard) | |
DSH083BN | Normally Closed, Selector | Electrical | 2-1 De-energized, 2-3 Energized | 5000 PSI, 350 BAR | 4 GAL/MIN, 15 L/MIN | Nitrile | |
DSH083BT | Normally Closed, Selector | Electrical, Manual | 2-1 De-energized, 2-3 Energized | 5000 PSI, 350 BAR | 4 GAL/MIN, 15 L/MIN | D-Ring (Standard) | |
DSH083BTN | Normally Closed, Selector | Electrical, Manual | 2-1 De-energized, 2-3 Energized | 5000 PSI, 350 BAR | 4 GAL/MIN, 15 L/MIN | Nitrile | |
DSH083BTV | Normally Closed, Selector | Electrical, Manual | 2-1 De-energized, 2-3 Energized | 5000 PSI, 350 BAR | 4 GAL/MIN, 15 L/MIN | Fluorocarbon | |
DSH083BV | Normally Closed, Selector | Electrical | 2-1 De-energized, 2-3 Energized | 5000 PSI, 350 BAR | 4 GAL/MIN, 15 L/MIN | Fluorocarbon | |
DSH083C | Normally Open | Electrical | 3-1 De-energized, 2-1 Energized | 5000 PSI, 350 BAR | 4 GAL/MIN, 15 L/MIN | D-Ring (Standard) | |
DSH083CN | Normally Open | Electrical | 3-1 De-energized, 2-1 Energized | 5000 PSI, 350 BAR | 4 GAL/MIN, 15 L/MIN | Nitrile | |
DSH083CT | Normally Open | Electrical, Manual | 3-1 De-energized, 2-1 Energized | 5000 PSI, 350 BAR | 4 GAL/MIN, 15 L/MIN | D-Ring (Standard) | |
DSH083CTN | Normally Open | Electrical, Manual | 3-1 De-energized, 2-1 Energized | 5000 PSI, 350 BAR | 4 GAL/MIN, 15 L/MIN | Nitrile | |
DSH083CTV | Normally Open | Electrical, Manual | 3-1 De-energized, 2-1 Energized | 5000 PSI, 350 BAR | 4 GAL/MIN, 15 L/MIN | Fluorocarbon | |
DSH083CV | Normally Open | Electrical | 3-1 De-energized, 2-1 Energized | 5000 PSI, 350 BAR | 4 GAL/MIN, 15 L/MIN | Fluorocarbon | |
DSH103A | Normally Closed, Normally Open, Selector | Electrical | 2-1 De-energized, 3-1 Energized | 5000 PSI, 350 BAR | 4, 4.5 GAL/MIN, 15, 17 L/MIN | D-Ring (Standard) | |
DSH103AN | Normally Closed, Normally Open, Selector | Electrical | 2-1 De-energized, 3-1 Energized | 5000 PSI, 350 BAR | 4, 4.5 GAL/MIN, 15, 17 L/MIN | Nitrile | |
DSH103AT | Normally Closed, Normally Open, Selector | Electrical, Manual | 2-1 De-energized, 3-1 Energized | 5000 PSI, 350 BAR | 4, 4.5 GAL/MIN, 15, 17 L/MIN | D-Ring (Standard) | |
DSH103ATN | Normally Closed, Normally Open, Selector | Electrical, Manual | 2-1 De-energized, 3-1 Energized | 5000 PSI, 350 BAR | 4, 4.5 GAL/MIN, 15, 17 L/MIN | Nitrile |
Description
Les électrovannes à tiroir 3 voies et 2 positions à commande directe de Parker présentent une conception éprouvée qui assure des performances à la fois fiables et prévisibles avec une faible perte de charge et une faible hystérésis. Ces électrovannes peuvent fonctionner avec des débits des systèmes hydrauliques de l’ordre de 57 l/m (15 g/m) et avec des pressions atteignant 350 bar (5 000 psi), dans les configurations normalement ouverte, normalement fermée ou à sélecteur. Les électrovannes à tiroir 3 voies et 2 positions de Parker sont conçues pour les applications de commutation ou de déchargement qui n’exigent pas nécessairement une faible fuite de type clapet, mais seulement des commandes directionnelles simples pilotées par des solénoïdes. Ces vannes peuvent être utilisées sur un large éventail de machines des secteurs de l’équipement mobile, de l’industrie et de la fabrication.
Marchés :
• Aérien
• Agriculture
• Construction
• Manutention des matières
• Divers industrie
• Diverses fabrications
• Divers mobile
Caractéristiques/Avantages :
• Bobines monoblocs remplaçables à faible ampérage
• Débit élevé
• Options de commande manuelle
• Corps et logements standard
• Pas de joints dynamiques
• Hystérésis faible
• Parties externes galvanisées
Applications :
• Applications de commutation
• Applications de déchargement
• Applications de répartiteur
Informations techniques supplémentaires :
Les distributeurs à tiroir à commande directe réagissent rapidement à l'excitation de la bobine et permettent au débit de circuler entre les 2 orifices tout en bloquant l’orifice restant. Un faible niveau de fuite dû au jeu des tiroirs est constaté.