Soupape de réduction de pression autopilotée avec montage sur embase
Description
As versatile pilot operated pressure reducing valves for subplate mounting, Parker's series R4R with manual adjustment and series R4R*P2 with proportional solenoid adjustment provide high flow and ensure a constant pressure in the secondary part of the hydraulic system. Independent of the primary pressure, the secondary pressure is reduced to the pressure setting. In order to avoid unintended motion of the actuator, the valves are normally closed...
Caractéristiques techniques
Plage de régulation de pression | 350 bar |
---|---|
Type de contrôle de réglage de pression | Hand knob |
Tension d'entrée | N/A |
Matériau du joint | NBR |
Pression de service maximale | Port A, B, X 350 bar; port Y depressurized |
Emplacements de la vidange/l'entrée pilote | Internal, drain external from Y |
Type de fonctionnement | Pilote |
Type de montage | Montage sur embase |
Raccordement d'orifice | NG32 / CETOP 10 |
Type de commande | Manuellement |
Série de produits | Valve de pression |
Division | Industrial Systems Division Europe |
Poids | 4.4 kg |
Pays d'origine | France |
Référence Fluidexpert | VDP0112 |
Référence Parker Denison | 016-86136-0 |
Fichiers
Type | Langue | Format |
---|---|---|
Fiche technique | Français | |
Fiche technique | Français | |
Fiche technique | Français | |
Fiche technique | Français | |
Fiche technique | Français | |
Fiche technique | Français | |
Fiche technique | Français | |
Fiche technique | Français |