Soupape de réduction de pression autopilotée R4R/R4R*P2
Description
As versatile pilot operated pressure reducing valves for subplate mounting, Parker's series R4R with manual adjustment and series R4R*P2 with proportional solenoid adjustment provide high flow and ensure a constant pressure in the secondary part of the hydraulic system. Independent of the primary pressure, the secondary pressure is reduced to the pressure setting. In order to avoid unintended motion of the actuator, the valves are normally closed...
Caractéristiques techniques
Raccordement d'orifice | NG25 / CETOP 08 |
---|---|
Emplacements de la vidange/l'entrée pilote | Internal, drain external from Y |
Plage de régulation de pression | 210 bar |
Tension d'entrée | N/A |
Pression de service maximale | Port A, B, X 350 bar; port Y depressurized |
Type de fonctionnement | Pilote |
Poids | 13.5 kg |
Type de contrôle de réglage de pression | Hand knob |
Matériau du joint | NBR |
Type de commande | Manuellement |
Division | Industrial Systems Division Europe |
Série de produits | Valve de pression |
Type de montage | Montage sur embase |
Poids | 4.4 kg |
Pays d'origine | France |
Référence Fluidexpert | VDP0086 |
Référence Parker Denison | 016-95331-0 |
Fichiers
Type | Langue | Format |
---|---|---|
Fiche technique | Français | |
Fiche technique | Français | |
Fiche technique | Français | |
Fiche technique | Français | |
Fiche technique | Français | |
Fiche technique | Français | |
Fiche technique | Français | |
Fiche technique | Français |