Soupape de réduction de pression autopilotée R4R/R4R*P2
Description
As versatile pilot operated pressure reducing valves for subplate mounting, Parker's series R4R with manual adjustment and series R4R*P2 with proportional solenoid adjustment provide high flow and ensure a constant pressure in the secondary part of the hydraulic system. Independent of the primary pressure, the secondary pressure is reduced to the pressure setting. In order to avoid unintended motion of the actuator, the valves are normally closed...
Caractéristiques techniques
| Emplacements de la vidange/l'entrée pilote | Internal, drain external from Y |
|---|---|
| Tension d'entrée | N/A |
| Type de contrôle de réglage de pression | Acorn nut with lead seal |
| Série de produits | Valve de pression |
| Plage de régulation de pression | 105 bar |
| Raccordement d'orifice | NG32 / CETOP 10 |
| Poids | 13.5 kg |
| Pression de service maximale | Port A, B, X 350 bar; port Y depressurized |
| Matériau du joint | NBR |
| Type de montage | Montage sur embase |
| Type de fonctionnement | Pilote |
| Type de commande | Manuellement |
| Division | Industrial Systems Division Europe |
| Poids | 4.4 kg |
| Pays d'origine | France |
| Référence Fluidexpert | VDP0110 |
| Référence Parker Denison | R4R10-59131B1 |